8. The Acve Air Chimney
The innovave Nanoxia Acve Air Chimney allows the easy dissipaon of hot air in case of a
heat buildup under the top cover: Once the Air Chimney is opened, the connected fans are
automacally acvated. When the Acve Air Chimney is closed, the fans are switched o
again.
8.1 Connecng the fans to the Acve Air Chimney
At the back of the motherboard tray, you can nd a circuit board to which you can connect up
to three fans. It is powered by a 3-pin Molex connector that is connected directly to the power
supply.
To connect fans to the Acve Air Chimney, rst you need to remove the right side panel (seen
from the front) and the top cover (see chapter 5.2). Next, connect the fans to connectors
labeled the F1, F2 and F3 on the circuit board.
Then put the cover back on the case. As a
last step, please connect the cable from the
switch of the Acve Air Chimney back to the
circuit board (see drawing).
FAN3 FAN2 FAN1
POWER
SWITCH
8.2 Operaon of the Acve Air Chimney
In order to open the Air Chimney, slid the dial to the “open” posion. This automacally
acvates the pre-installed case fans under the top cover. To close the Air Chimney simply slide
the tab back in the opposite posion. This will also deacvate the fans.